Model NO.: YSD220
Reaction Temperature: 37±0.2°c
Temperature Fluctuation: ± 0.2°c
Gross Weight: 45kg
Warranty: 12 Months
Trademark: YSD
Transport Package: Standard Export Package
Specification: 78*58*55cm
Origin: Chengdu, China
HS Code: 9027809900
Model NO.: YSD220
Reaction Temperature: 37±0.2°c
Temperature Fluctuation: ± 0.2°c
Gross Weight: 45kg
Warranty: 12 Months
Trademark: YSD
Transport Package: Standard Export Package
Specification: 78*58*55cm
Origin: Chengdu, China
HS Code: 9027809900
YSD-220 Fully-auto Biochemistry Analyzer




 Bench-Top Full Automatic Biochemistry Analyzer

 
 

Features
  • Random access, discrete automatic biochemistry analyzer, insert emergency at any time
  • High performance and reasonable price, It is the best economical choice from semi-auto upgraded to fully-auto analyzer
  • Probe performance: Liquid level detection, all-round anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle
  • Probe cleaning: Automatic washing for both interior and exterior
 
Bench-Top Full Automatic Biochemistry Analyzer



Analysis System

Bench-Top Full Automatic Biochemistry Analyzer

 
  • Test Speed: constant 160tests/hour, up to 220tests/hour
  • Test method: End-point, Fixed-time (two point method), kinetic
  • Reaction tray:  81 UV cuvettes (disposable)
  • Mini reaction volume: 150μl, save reagent cost
  • Insert emergency at any time
  • Support linear and non-linear calibration
  • Heating method: solid constant temperature closed direct heating
  • Temperature equilibrium time: less than 3minutes,
  • Reaction Temperature: 37±0.2°C
  • Temperature Fluctuation: ± 0.2°C
 
Optical System

Bench-Top Full Automatic Biochemistry Analyzer
 
  • Integrated full closed optical system, after spectrometric method, no mechanical parts, not moldy, no maintenance cost
  • 8 wavelengths, selectable among 340-800nm
  • Absorption range: 0.00-4.00Abs
  • Halogen-tungsten lamp has more than 2000hrs service time
  • Center wavelength deviation: ±2nm, half wave width less than 12nm
  • Stray light less than 0.3%
  • Resolution: 0.0001Abs
 
Reagent/Sample Tray

Bench-Top Full Automatic Biochemistry Analyzer
 
  • 60 reagent + 30 sample positions
  • Advanced reagent tray refrigeration system, temperature: 4-12°C (optional function)
  • Automatically detect reagent remain, real time display reagent remain
  • Reagent bottles with 15ml,30ml,50ml,70ml are available.
  • Support single/ dual reagents, reagents are open
  • Real time display reagent tray status
  • Automatically judge substrate depletion
 
Sample adding and rinsing system

Bench-Top Full Automatic Biochemistry Analyzer
 
  • Sample volume:             2-100μl , 0.1μl by step,
  • Reagent volume:                    20-500μl, 1μl by step
  • Water consumption:     less than 3L/hour
 
 

Operation System
  • Windows XP or Windows 7 Home, easy to operate
  • Automatic storage, automatic backup, no time limit and storage limit,
  • Permanently preserve all kinds of data
  • English print report, the user can modify the print format
  • English online help and operation guide
  • The test parameter setting is completely open
  • Real-time monitor the status of sample tray, reagent tray and reaction tray
  • Real-time monitor the status of reaction cup, lamp and purified water
  • Real-time display the reaction tray humidity and reagent remain
  • Real-time display the reaction curve, calibration curve and QC chart
  • Automatically check calibration curve and select the calibration type with the best fitting
  • Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
  • Inspection and Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, reaction limit inspection, reagent blank absorbance judgment
  • RS232 standard interface, support the intranet and remote printing
 

Technical Specifications                
                                      

Performance
Type: Discrete Automatic, Random Access
Principle:   Absorption Spectrometry, Turbidimetry
Throughput: Constant 160tests/hour (without ISE)
Test method: End-point, Fixed-time, Kinetic
                    Support dual reagents/double wavelength
Test sequence: Run tests in strict accordance with sample sequence,
                       Insert emergency at any time

Optical System

Light Source:  Halogen-tungsten lamp, 12V/20W
                      More than 2000hrs service time
Spectrometric Method:  After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Absorption Range:  0-4.0Abs
Optical System: Integrated full closed optical system
 

Reaction system

Reaction Tray:  81 positions for cuvettes
Reaction Volume: Mini 150μl
 

Sample system

Sample Tray:  30 positions
Sample Volume: 2-100μl, 0.1μl by step
Online Sample: 30 samples/ batch, unlimited batch input
 

Reagent System

Reagent Tray:  60 positions, open system
Reagent Volume:  20-500μl, 1μl by step
Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are available dead volume<1ml
 

Temperature Control System

Heating Mode: Solid constant temperature closed direct heating
Equilibrium Time: less than 3minutes
Reaction Temperature:  37±0.2°C
Temperature Fluctuation: ± 0.2°C
Refrigeration system: For option
 

Calibration and QC

Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
                            Automatically check calibration curve and select the calibration type with the best fitting
QC Type: Real time QC, QC in one day, QC between days;
QC Rules: QC chart: L-J, Cumulative, Twin Plot, Multi-rule; default: Westguard
Status Monitoring:  Real -time monitor the sample tray, reagent tray, reaction tray, reaction cup, lamp, purified water; Real-time display reaction tray humidity, reagent remain, reaction curve, calibration curve and QC chart.
Inspection & Judgment:  Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, front belt detection,reaction limit inspection, reagent blank absorbance judgment
 

Operation and Print

Operation System: Windows XP or Windows 7 Home
Database: SQL Server
Data Storage: Automatic storage and backup, permanently preserve all kinds of data
Print Content: Print content can be customized
Print Format: Provide a variety of print format
 

Working Conditions

Water Consumption: less than 3L/hour
Power Supply: AC 220 ±22V   50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 10°C-30°C
Dimension(L*W*H): 78*58*55cm
Net Weight:  45KGS



Why choose us:

We got production and business certification from Chengdu food and Drug Administration
We got business license from Chengdu City Administration of industry and commerce
We got products certificate of registration and have checked in the website of SFDA
We have accepted the onsite check from SFDA every quarter
We finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;

  YSD-220 Fully-auto Biochemistry Analyzer




 Bench-Top Full Automatic Biochemistry Analyzer

 
 

Features
  • Random access, discrete automatic biochemistry analyzer, insert emergency at any time
  • High performance and reasonable price, It is the best economical choice from semi-auto upgraded to fully-auto analyzer
  • Probe performance: Liquid level detection, all-round anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle
  • Probe cleaning: Automatic washing for both interior and exterior
 
Bench-Top Full Automatic Biochemistry Analyzer



Analysis System

Bench-Top Full Automatic Biochemistry Analyzer

 
  • Test Speed: constant 160tests/hour, up to 220tests/hour
  • Test method: End-point, Fixed-time (two point method), kinetic
  • Reaction tray:  81 UV cuvettes (disposable)
  • Mini reaction volume: 150μl, save reagent cost
  • Insert emergency at any time
  • Support linear and non-linear calibration
  • Heating method: solid constant temperature closed direct heating
  • Temperature equilibrium time: less than 3minutes,
  • Reaction Temperature: 37±0.2°C
  • Temperature Fluctuation: ± 0.2°C
 
Optical System

Bench-Top Full Automatic Biochemistry Analyzer
 
  • Integrated full closed optical system, after spectrometric method, no mechanical parts, not moldy, no maintenance cost
  • 8 wavelengths, selectable among 340-800nm
  • Absorption range: 0.00-4.00Abs
  • Halogen-tungsten lamp has more than 2000hrs service time
  • Center wavelength deviation: ±2nm, half wave width less than 12nm
  • Stray light less than 0.3%
  • Resolution: 0.0001Abs
 
Reagent/Sample Tray

Bench-Top Full Automatic Biochemistry Analyzer
 
  • 60 reagent + 30 sample positions
  • Advanced reagent tray refrigeration system, temperature: 4-12°C (optional function)
  • Automatically detect reagent remain, real time display reagent remain
  • Reagent bottles with 15ml,30ml,50ml,70ml are available.
  • Support single/ dual reagents, reagents are open
  • Real time display reagent tray status
  • Automatically judge substrate depletion
 
Sample adding and rinsing system

Bench-Top Full Automatic Biochemistry Analyzer
 
  • Sample volume:             2-100μl , 0.1μl by step,
  • Reagent volume:                    20-500μl, 1μl by step
  • Water consumption:     less than 3L/hour
 
 

Operation System
  • Windows XP or Windows 7 Home, easy to operate
  • Automatic storage, automatic backup, no time limit and storage limit,
  • Permanently preserve all kinds of data
  • English print report, the user can modify the print format
  • English online help and operation guide
  • The test parameter setting is completely open
  • Real-time monitor the status of sample tray, reagent tray and reaction tray
  • Real-time monitor the status of reaction cup, lamp and purified water
  • Real-time display the reaction tray humidity and reagent remain
  • Real-time display the reaction curve, calibration curve and QC chart
  • Automatically check calibration curve and select the calibration type with the best fitting
  • Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
  • Inspection and Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, reaction limit inspection, reagent blank absorbance judgment
  • RS232 standard interface, support the intranet and remote printing
 

Technical Specifications                
                                      

Performance
Type: Discrete Automatic, Random Access
Principle:   Absorption Spectrometry, Turbidimetry
Throughput: Constant 160tests/hour (without ISE)
Test method: End-point, Fixed-time, Kinetic
                    Support dual reagents/double wavelength
Test sequence: Run tests in strict accordance with sample sequence,
                       Insert emergency at any time

Optical System

Light Source:  Halogen-tungsten lamp, 12V/20W
                      More than 2000hrs service time
Spectrometric Method:  After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Absorption Range:  0-4.0Abs
Optical System: Integrated full closed optical system
 

Reaction system

Reaction Tray:  81 positions for cuvettes
Reaction Volume: Mini 150μl
 

Sample system

Sample Tray:  30 positions
Sample Volume: 2-100μl, 0.1μl by step
Online Sample: 30 samples/ batch, unlimited batch input
 

Reagent System

Reagent Tray:  60 positions, open system
Reagent Volume:  20-500μl, 1μl by step
Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are available dead volume<1ml
 

Temperature Control System

Heating Mode: Solid constant temperature closed direct heating
Equilibrium Time: less than 3minutes
Reaction Temperature:  37±0.2°C
Temperature Fluctuation: ± 0.2°C
Refrigeration system: For option
 

Calibration and QC

Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
                            Automatically check calibration curve and select the calibration type with the best fitting
QC Type: Real time QC, QC in one day, QC between days;
QC Rules: QC chart: L-J, Cumulative, Twin Plot, Multi-rule; default: Westguard
Status Monitoring:  Real -time monitor the sample tray, reagent tray, reaction tray, reaction cup, lamp, purified water; Real-time display reaction tray humidity, reagent remain, reaction curve, calibration curve and QC chart.
Inspection & Judgment:  Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, front belt detection,reaction limit inspection, reagent blank absorbance judgment
 

Operation and Print

Operation System: Windows XP or Windows 7 Home
Database: SQL Server
Data Storage: Automatic storage and backup, permanently preserve all kinds of data
Print Content: Print content can be customized
Print Format: Provide a variety of print format
 

Working Conditions

Water Consumption: less than 3L/hour
Power Supply: AC 220 ±22V   50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 10°C-30°C
Dimension(L*W*H): 78*58*55cm
Net Weight:  45KGS



Why choose us:

We got production and business certification from Chengdu food and Drug Administration
We got business license from Chengdu City Administration of industry and commerce
We got products certificate of registration and have checked in the website of SFDA
We have accepted the onsite check from SFDA every quarter
We finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;

 

The working principle of the centrifugal separator includes centrifugal filtration and centrifugal sedimentation. Centrifugal filtration is the centrifugal pressure generated by the suspension under the centrifugal force field, acting on the filter medium, so that the liquid passes through the filter medium to become a filtrate, and the solid particles are trapped on the surface of the filter medium, thereby achieving liquid-solid separation; centrifugal sedimentation is to use The principle that each component with different density of suspension (or emulsion) settles quickly in the centrifugal force field to achieve liquid-solid (or liquid-liquid) separation.

centrifuge machine

centrifuge machine, centrifuge seperation machine, oil water seperator machine

Henan Gems Machinery Co.,Ltd , https://www.gemsmachine.com