Nowadays, the weather is getting warmer and warmer. Many radiators also have some problems after they are stopped. Therefore, it is necessary to install a heating cooker on the side of the house. This is a good comparison. The radiators look quiet and not used. In fact, the radiator is also a consumable product, especially when used in winter, high temperature and high pressure on the radiator test is also very large, so a long time, there will be damaged radiator replacement, the following look at the replacement of heating The use of sheets and radiators and precautions.



Replacement heating installation process

1. If you replace the radiator, users should try to choose the size of the radiator according to the original radiator's heat dissipation. If the original radiator can't be obtained, it needs to be estimated based on the size of the house, orientation, floor, and window size.

2, replace the radiator should pay attention to is that if the user community belongs to a household a valve, then need to close the valve, and then replace the heating preparation. If the user community belongs to the collective collective heating, it is necessary to reform the heating pipeline in advance. Otherwise, closing the valve will affect the neighbor's heating. Therefore, a pipeline must be connected to connect the inlet and outlet to form an overall series system to ensure the normal circulation of hot water. In short, you must find a professional to operate as well.

3. The original radiator installation location and pipe connection method are not installed arbitrarily. They are all rationally designed and set according to the characteristics of the unit type, district heating system design, and the degree of house insulation. If excessive changes are made, it will destroy the original The system balances and buries a large number of safety hazards. The occurrence of leaking and bursting of radiators increases. Therefore, when the user replaces the radiator, he or she should try to change the pipeline as little as possible, and the installation position should give priority to the location of the original radiator.

4. During the replacement of the radiator, the safety and airtightness are the most critical, and care must be taken to ensure that there is no leakage. The heating system is a durable consumer product that requires a period of verification. Therefore, the necessary tests are indispensable. Usually, when the replacement is performed, the worker will set aside a valve for the pipeline. After the installation, a stamping test shall be conducted to prove that no running, running, or dropping Leakage is acceptable.

Radiator use method

1. When using a radiator, you can turn off or turn down the radiator in an unoccupied room. However, if the radiator fails for a long period of time, precautions should be taken to prevent freezing. If necessary, empty the water in the radiator.

2. Air bleed valve: The deflation valve is needed when the radiator does not have some heat. Open the air release valve and let the gas out until the gas is exhausted. When there is water overflow, close the air release valve.

3, heating season, the valve should not be constantly switched, the valve can only be in full open or fully closed state; within three days after the stop warm touch the pipe connection, check the interface is leaking, if leakage, then immediately notify the professional maintenance.



4. If the housing area is large, the rooms are large, and the population is relatively small, then the radiator valves of the unoccupied or low-usage rooms can be completely closed or reduced, which is equivalent to the reduction of the heating area. Not only energy-saving, but also in the normal use of space heating temperature will increase, reducing gas consumption.

In other seasons, it will be eroded by external substances, and rusting will occur. After many years of use, replacing the radiator is something that every family must go through. For everyone, we introduce some of the radiator replacement and use methods, hoping to Help.

Shanghai Shure Environmental Technology Co., Ltd. Tel

JXHS series Junction Box advanced technology during production, stresses the details during design, implements design standard during processing, and has high consistence of product quality. It has various features such as strong damp proof, anti-corrosion and anti-electromagnetic capacities and high adjustment accuracy, and is suitable for various adverse environments. Its main advantages include:
The product uses own mold to make technologic design, the housing uses aluminum and silicon alloy and upper protrusion and lower sinking structure is used so as to ensure good sealing performance; protective grade reaches IP 68.
Main parts are imported, wiring bar is welded with precise anti-surge electronic components, which can prevent Load Cell damage caused by lightning and power grid surge voltage.
Whole device uses stainless steel grounding bolts to ensure reliable grounding during operation.
Assembly of junction box uses not-loose screws so as to avoid loss during load cell wring.
Wiring board uses combined screws for assembly, which are convenient for removal.
In order to ensure protective effect, force and diameter of tightening parts have introduction.

Digital Explosion Proof Junction Box

Outdoor Junction Box,Digtal Junction Box With 10-Wire,Digtal Explosion-Proof Junction Box With 6-Port,Digital Explosion Proof Junction Box

SHANDONG JINZHONG SCIENCE & TECHNOLOGY GROUP COMPANY LIMITED , https://www.chinagoldbell.com